Description
2 ft x 2 ft Back Lit Panel Factory-Installed Emergency Backup | 1,040-Lumen Emergency Output | 90-Minute Runtime | 120-277V | 0-10V Dimming
This 2x2 emergency back-lit LED panel light combines five selectable wattage settings, five selectable color temperatures and a factory-installed 8W emergency driver in one contractor-ready ceiling fixture. During normal operation, the panel can be set to 20W, 25W, 30W, 35W or 40W and 3000K, 3500K, 4000K, 5000K or 6500K. If normal power is lost, the emergency system provides a minimum 90-minute runtime at a nominal calculated output of 1,040 lumens. The test switch and charging indicator are included for required inspection and maintenance.
Product Specifications
- Product Type: Emergency back-lit LED panel light
- Fixture Size: 2 x 2 feet
- Mounting Type: Recessed installation in conventional grid ceilings
- Normal Input Voltage: 120-277V AC
- Selectable Wattage: 20W, 25W, 30W, 35W or 40W
- Wattage Control: Five-position selector switch
- Selectable CCT: 3000K, 3500K, 4000K, 5000K or 6500K
- CCT Control: Five-position selector switch
- Maximum Efficacy: Up to 130 lm/W
- CRI: Greater than 80
- Dimming: 0-10V
- Power Factor: Greater than 0.95 at full load
- Total Harmonic Distortion: Less than 15% at full load
- Emergency Driver: Factory-installed 8W LED emergency driver
- Emergency Output: Nominal 1,040 lumens based on 8W at 130 lm/W
- Emergency Runtime: Minimum 90 minutes
- Emergency Recharge Time: 24 hours
- Emergency Test Switch: Included
- Charging Indicator: Included
- Emergency Compliance: ETL Listed to UL 924 emergency-lighting standards
- Housing: White high-strength metal frame
- Lens Assembly: PMMA lens with polystyrene diffuser
- Lighting Appearance: Uniform illumination designed to reduce hot spots, shadows and glare
- Fixture Dimensions: 23.74 inches long x 23.74 inches wide x 1.38 inches high
- Operating Temperature: -22 F to 104 F
- Estimated Rated Life: Greater than 54,000 hours at 77 F
- Normal Fixture Warranty: 5 years
- Emergency Driver Warranty: 5 years
Benefits
- Factory-installed emergency driver eliminates the need to field-mount a separate backup system above the ceiling.
- Provides a minimum 90 minutes of emergency illumination after normal power is lost.
- Included test switch and charging indicator simplify inspection and routine emergency-system testing.
- Five selectable wattages allow one fixture to cover multiple room sizes and lighting requirements.
- Five selectable color temperatures allow contractors to match the project specification during installation.
- 0-10V dimming supports compatible wall controls, occupancy systems and commercial energy-management systems.
- Back-lit construction provides uniform illumination while reducing visible hot spots, shadows and glare.
- Low-profile 1.38-inch housing fits conventional suspended grid ceilings.
- 120-277V input supports common commercial branch voltages.
- ETL listing to UL 924 standards supports emergency egress-lighting applications.
Applications
- Offices and administrative areas
- Schools and classrooms
- Hospitals and healthcare facilities
- Retail stores and shopping centers
- Commercial corridors and hallways
- Emergency egress paths
- Conference rooms
- Institutional buildings
- Government facilities
- Reception areas and waiting rooms
- Tenant improvement projects
- Replacement of fluorescent 2x2 troffers
Downloads
Factory-Installed 8W Emergency Driver
The emergency driver is installed before the fixture ships, reducing field labor and eliminating the need to select, mount and wire a separate emergency system. The emergency components are integrated with the panel and include the required test switch and charging indicator.
When normal power is interrupted, the emergency driver operates the LED panel at 8 watts for a minimum of 90 minutes. Based on the panel's listed maximum efficacy of 130 lm/W, the nominal calculated emergency output is approximately 1,040 lumens.
Emergency Testing and Charging Indicator
The included test switch allows maintenance personnel to simulate a power failure and verify emergency operation. The charging indicator provides a visible status reference for the emergency system. Follow the applicable inspection schedule and local emergency-lighting requirements after installation.
Allow up to 24 hours for the emergency battery system to reach a full charge before completing the initial full-duration emergency test.
Five Selectable Wattage Settings
Switch 1 sets the panel to 20W, 25W, 30W, 35W or 40W during normal operation. Contractors can use one fixture for several room types and adjust the connected load and light output during installation without ordering separate wattage-specific models.
The lower settings can be used in smaller rooms or areas requiring reduced light output. The 40W setting provides the highest normal operating output for larger rooms and higher ambient-light requirements.
Five Selectable Color Temperatures
Switch 2 selects 3000K, 3500K, 4000K, 5000K or 6500K. This allows the panel to match different project specifications, existing fixtures and room functions without changing the complete luminaire.
Select 3000K or 3500K for a warmer appearance, 4000K for a balanced commercial white, 5000K for a daylight appearance or 6500K for the coolest available setting. Confirm the project specification before commissioning the fixture.
Uniform Back-Lit Illumination
The back-lit optical system uses a PMMA lens and polystyrene diffuser to distribute light evenly across the panel face. This construction is designed to reduce hot spots, visible shadows and uncomfortable glare in classrooms, offices, healthcare spaces and other occupied interiors.
0-10V Dimming
The panel supports 0-10V dimming with compatible controls. The purple dimming lead connects to dim positive, and the pink dimming lead connects to dim negative. Dimming controls and low-voltage control wiring are not included unless specifically stated.
Optional Motion and Bluetooth Controls
The panel is compatible with optional plug-and-play microwave motion sensors and Bluetooth-enabled controls. Available control functions may include occupancy detection, daylight response, standby dimming, scheduling, high-end trim and energy monitoring. Sensors, remote controls and Bluetooth accessories are sold separately.
Before You Order
Confirm that the ceiling uses a conventional 2x2 suspended grid and that the available branch voltage is between 120V and 277V. Verify that the project requires an emergency panel with a factory-installed 8W emergency driver and a minimum 90-minute runtime.
Confirm the required normal wattage and color temperature before final commissioning. The fixture can be adjusted after installation, but both selector switches should be set and documented before the ceiling work is completed.
Emergency illumination requirements vary by room layout, fixture spacing, mounting height and local code. The nominal 1,040-lumen emergency output should be evaluated as part of the complete emergency egress-lighting design.
What Is Included
The fixture includes the 2x2 back-lit LED panel, integrated LED driver, five-position wattage selector, five-position CCT selector, factory-installed 8W emergency driver, emergency battery system, test switch, charging indicator and installation wiring.
What Is Not Included
The suspended ceiling grid, branch-circuit wiring, 0-10V dimmer, occupancy sensor, Bluetooth control, remote control and other optional control accessories are not included unless specifically stated on the order.
Installation
Installation must be completed by a qualified electrician in accordance with the National Electrical Code, UL 924 requirements and applicable local codes. Disconnect normal and emergency power before installation or service.
Place the fixture into the conventional ceiling grid, connect line, neutral and ground conductors, and connect the 0-10V dimming leads when required. Complete all emergency-driver connections according to the supplied wiring instructions. Set the normal wattage and CCT switches before completing installation.
After power is applied, confirm that the charging indicator is operating. Allow the emergency battery to charge for 24 hours before completing a full 90-minute discharge test.
Frequently Asked Questions
Is the emergency driver already installed?
Yes. The 8W LED emergency driver is factory installed in the fixture.
How long will the panel operate during a power outage?
The emergency system provides a minimum runtime of 90 minutes.
How much light does it provide in emergency mode?
The nominal calculated emergency output is approximately 1,040 lumens based on 8 watts at 130 lm/W.
How long does the emergency battery take to recharge?
Allow up to 24 hours for a full recharge.
Are the test switch and charging indicator included?
Yes. Both components are included with the factory-installed emergency system.
Is the emergency system UL 924 compliant?
The emergency configuration is ETL Listed to UL 924 emergency-lighting standards.
What wattages can be selected?
The panel can be set to 20W, 25W, 30W, 35W or 40W.
What color temperatures are available?
The panel can be set to 3000K, 3500K, 4000K, 5000K or 6500K.
Is the panel dimmable?
Yes. It supports 0-10V dimming with compatible controls.
What ceiling type does it fit?
It is designed for recessed installation in a conventional 2x2 suspended grid ceiling.
What warranty is included?
The LED panel and factory-installed emergency driver include a 5-year warranty.