Description
Emergency LED Backup Driver | 10W Constant Output | 120-277V Input | 90-Minute Runtime | Non-Dimmable
Ace LEDS ACEPH101555CP is a 10W linear emergency LED driver that adds reliable backup operation to compatible LED fixtures, delivering 15-55V DC emergency output, 180-670mA output current, 120-277V universal input, and a minimum 90-minute runtime from a LiFePO4 battery. Built with Power Activate self-start functionality, a slim metal enclosure, an illuminated test switch, and protection against surge, short-circuit, open-circuit, over-voltage, and over-temperature conditions, this UL924 emergency driver is designed for indoor and damp-location commercial LED fixture applications.
Product Specifications
- Model: Ace LEDS ACEPH101555CP
- Product Type: Linear Emergency LED Driver
- Emergency Output Power: 10W Constant
- Input Voltage: 120-277V AC, 50/60Hz
- Input Power: 8W
- Input Current: 110mA Max
- Emergency Output Voltage: 15-55V DC
- Absolute Maximum Output Voltage: 60V
- Emergency Output Current: 180-670mA
- Emergency Runtime: 90 Minutes Minimum
- Battery Type: LiFePO4
- Nominal Battery Voltage: 6.4V
- Battery Capacity: 3300mAh
- Battery Charge Current: 185mA
- Battery Recharge Time: 24 Hours Max
- Battery Life Expectancy: 7 to 10 Years
- Ambient Operating Temperature: 0°C to 55°C
- Maximum Case Temperature: 66°C
- Normal AC Driver Maximum Output Current: 5A
- Surge Protection: 3kVp
- Enclosure Rating: IP30 Metal Enclosure
- Dimensions: 9.5" L x 1.7" W x 1.2" H
- Mounting Length: 8.9"
- Maximum Remote Mounting Distance: 18 ft from LEDs
- Lead Wire: 18 AWG, 600V, 105°C Stranded Copper
- Test Switch: Miniature Illuminated Test Switch Status Indicator
- Installation Type: Field or Factory Installation
- Location Rating: Indoor and Damp Locations
- Output Classification: Class 2 Compliant
- Warranty: 5 Years at ≤60°C Case Temperature; 3 Years at ≤66°C Case Temperature
- Certifications: UL and cUL Listed Emergency LED Driver, UL924, UL1310 Class 2 Output, CEC Title 20, FCC Commercial Limits, RoHS Compliant
Emergency Battery Backup Features
- Provides a minimum 90-minute emergency runtime for compatible LED fixtures
- Delivers constant 10W emergency output across the 15-55V DC output range
- Uses a LiFePO4 battery with 6.4V nominal voltage and 3300mAh capacity
- Recharges in 24 hours maximum when connected to normal AC power
- Designed with a 7 to 10 year battery life expectancy
- Power Activate feature eliminates the external battery connector during installation
- Automatically switches to emergency mode when normal AC power fails
- Returns to normal mode when AC power is restored
- Includes miniature illuminated test switch for manual testing and status indication
- Supports remote mounting up to 18 ft from the LED load
- Suitable for switched or unswitched fixture applications
- Requires unswitched constant hot connection to charge and maintain the battery
Benefits
- Adds emergency backup operation to compatible LED fixtures without requiring a separate emergency fixture
- Constant-power emergency output helps maintain stable light levels throughout the 90-minute runtime
- Universal 120-277V input supports common commercial and industrial electrical systems
- Two-wire input design helps reduce wiring errors and installation complexity
- Slim, low-profile metal enclosure fits compact luminaires and retrofit spaces
- Built-in protection supports safer and more reliable emergency lighting operation
- UL924 emergency driver listing supports code-focused commercial emergency lighting applications
- Field or factory installation rating gives contractors and fixture builders more flexibility
Applications
- Emergency backup for compatible LED fixtures
- Commercial LED fixture retrofits
- Linear LED luminaires
- Emergency-only LED fixtures
- New LED fixture builds
- Indoor emergency lighting systems
- Damp-location emergency lighting applications
- Sealed and gasketed LED fixtures
- Low-profile luminaires with limited internal space
Installation Notes
- The normal AC LED driver is not included
- The emergency driver must be installed on the same branch circuit as the normal AC LED driver when used
- The metal case should be grounded
- The unit is not suitable for air-handling or heated air outlets
- The battery is not replaceable; replace the entire unit when necessary
- Installation and service should be performed by qualified personnel