null

FREE SHIPPING ON ORDERS OF $1000 OR MORE*

High Wattage LED Bulbs

(Showing 24 of 385)

Shop high wattage LED bulbs built to deliver high lumen output for commercial, industrial and outdoor lighting applications. Compare LED corn cob bulbs, ED-shaped lamps and HID replacement LED bulbs for metal halide, high-pressure sodium and mercury vapor fixtures. Use the available filters to narrow the selection by HID equivalent, base, lumen output, LED wattage, operation type, voltage and other important specifications.

High-Lumen Commercial LED Bulbs and HID Retrofit Lamps

High wattage LED bulbs are used when a standard household LED bulb does not produce enough light or is not designed for the existing fixture. These high-output commercial lamps are commonly used in wall packs, post-top lights, area lights, high bays, parking lot fixtures, streetlights, security lights, shoebox fixtures and other demanding applications.

The selection may include LED corn cob bulbs, ED-shaped lamps such as ED17, ED23, ED28 and ED37 bulbs, BT lamps, A-shaped high-output bulbs and other screw-in HID retrofit lamps. Available base options may include E26 medium, E39 mogul and EX39 exclusionary mogul bases. Products vary by actual LED wattage, lumen output, HID equivalent, voltage, operation type, fixture rating, color temperature and physical dimensions. Review the full specifications on each product page before ordering.

Use the Filters to Narrow Your Selection

Use the available product filters to identify bulbs that match the requirements of your fixture and application. Depending on the products currently available, you may be able to narrow the category by:

  • HID Replacement Range: The metal halide, high-pressure sodium or mercury vapor wattage the LED lamp is rated to replace.
  • Base: Options may include E26 medium, E39 mogul and EX39 exclusionary mogul bases.
  • Operation Type: Type A plug-and-play, Type B ballast bypass or Type AB hybrid operation.
  • Maximum Lumens: The visible light output produced by the lamp.
  • Maximum LED Wattage: The actual electrical power consumed by the LED bulb.
  • Bulb Shape: Options may include corn cob, ED, A-shaped, BT and T-shaped lamps.
  • Color Temperature: Options may include fixed color temperatures such as 3000K, 4000K and 5000K, as well as selectable-color models when available.
  • Voltage: Match the lamp's rated voltage to the fixture's electrical supply and installation method.

Fixture descriptions such as post top, high bay, wall pack, shoebox and area light refer to common applications rather than bulb shapes. Always verify that the individual lamp is approved for the intended fixture.

What Is a High Wattage LED Bulb?

A high wattage LED bulb is a high-output lamp designed for applications that require more light than a typical household bulb. Actual LED wattage measures the electricity the lamp consumes, while lumens measure the visible light it produces.

Do not select an LED bulb by wattage alone. A newer or more efficient lamp may produce equal or greater lumen output while using fewer watts. When replacing an HID lamp, compare the LED bulb's lumen output and manufacturer-stated HID equivalent with the existing metal halide, high-pressure sodium or mercury vapor bulb.

Types of High Wattage and High-Lumen LED Bulbs

  • LED corn cob bulbs: High-lumen lamps with LEDs arranged around the body for multidirectional light distribution. They are commonly used in compatible post-top fixtures, wall packs, area lights, high bays and other commercial fixtures.
  • LED HID replacement bulbs: Retrofit lamps rated to replace specific metal halide, high-pressure sodium or mercury vapor lamps while keeping the existing fixture housing.
  • ED-shaped LED bulbs: High-output lamps shaped similarly to traditional HID bulbs. These may be useful when fixture clearance, lamp profile or light distribution is important.
  • Type A ballast-compatible lamps: Also called plug-and-play lamps. These operate on a compatible existing ballast, which must be verified by ballast model before installation.
  • Type B ballast-bypass lamps: Also called direct-wire lamps. The existing ballast must be disconnected or removed so line voltage can be supplied according to the manufacturer's instructions.
  • Type AB hybrid lamps: These support installation on a compatible ballast or direct-wire operation, depending on the manufacturer's instructions.
  • CCT-selectable lamps: These include a switch that allows the installer to choose from two or more available color temperatures.

How to Choose the Right High-Output LED Bulb

Compare the following specifications before selecting a replacement bulb:

  • Existing lamp type: Identify whether the current bulb is metal halide, pulse-start metal halide, high-pressure sodium, mercury vapor or another light source.
  • HID equivalent: Match the LED lamp to the manufacturer's stated replacement wattage rather than estimating compatibility from LED wattage alone.
  • Lumen output: Compare brightness in lumens and consider potential light loss through fixture lenses, reflectors and optical components.
  • Base: Confirm whether the socket uses an E26 medium, E39 mogul, EX39 exclusionary mogul or another base.
  • Operation type: Determine whether the lamp operates on a compatible ballast, requires ballast bypass or supports both installation methods.
  • Voltage: Verify that the lamp is rated for the fixture's supply voltage after any required rewiring.
  • Dimensions: Compare the maximum overall length and diameter with the available space inside the fixture, reflector and lens.
  • Burn position: Confirm whether the lamp may operate base-up, base-down, horizontally or in any position.
  • Fixture rating: Check whether the lamp is approved for open fixtures, enclosed fixtures, damp locations or wet locations as required.
  • Color temperature: Choose the preferred light appearance, such as 3000K warm white, 4000K neutral white or 5000K daylight, or select an adjustable-color lamp when available.

Suitability depends on the individual lamp and fixture. Do not assume that every high wattage LED bulb is approved for enclosed fixtures, outdoor use or operation on an existing HID ballast.

Common Applications for High-Lumen LED Bulbs

  • Outdoor post-top and streetlight fixtures
  • Parking lot, area and shoebox lights
  • Wall packs and security lights
  • Warehouse and industrial high bays
  • Parking garages and covered canopies
  • Bollards and pathway fixtures
  • Municipal and property-management lighting
  • Retail, school and commercial building lighting

Replacing Metal Halide or High-Pressure Sodium Bulbs with LED

An LED retrofit lamp can provide a practical way to upgrade an existing HID fixture without replacing the entire fixture housing. The correct conversion depends on the original bulb, ballast, socket, voltage, fixture dimensions and required lumen output.

Some LED lamps operate on specific compatible ballasts, while others require the existing ballast to be bypassed. Some hybrid lamps support either method. Ballast-bypass installation involves line-voltage wiring and should be performed by a qualified person in accordance with the product instructions and applicable electrical codes.

If you need a traditional HID lamp instead of an LED conversion, browse our metal halide light bulbs or high-pressure sodium light bulbs.

Who Should Shop High Wattage LED Bulbs?

This category serves electricians, contractors, facility managers, municipalities, property managers, maintenance departments and business owners who need high-output screw-in LED lamps. These products are especially useful when replacing an HID bulb inside a fixture that remains structurally sound.

Light Bulb Surplus offers high wattage LED bulbs from multiple commercial lighting manufacturers. Compare lumen output, actual LED wattage, HID equivalent, base, bulb shape, color temperature, voltage, physical dimensions and installation requirements to identify the appropriate lamp.

Products may be sold individually or in manufacturer package quantities. Review the pricing unit and package quantity shown on each product page before ordering.

Frequently Asked Questions

What is the difference between a high wattage LED bulb and a high lumen LED bulb?

Wattage measures the electricity an LED lamp uses, while lumens measure the amount of visible light it produces. Buyers often search for high wattage LED bulbs when they need a high-output or high-lumen lamp, so both specifications should be reviewed.

Can an LED bulb replace a metal halide bulb?

Yes, when the LED lamp is rated to replace the existing metal halide wattage and is compatible with the fixture, socket, voltage and installation method. Do not assume two lamps are interchangeable based only on shape or base.

Can an LED bulb replace a high-pressure sodium bulb?

Some LED HID replacement lamps are rated to replace high-pressure sodium bulbs. Confirm the original HPS wattage, base, ballast requirements, voltage, fixture dimensions and required lumen output before selecting a replacement. Standard white LED lamps will also produce a different light appearance than the amber output commonly associated with HPS lamps.

What do Type A, Type B and Type AB mean?

Type A lamps operate on a compatible existing ballast and are commonly described as plug-and-play. Type B lamps require the ballast to be bypassed so the socket receives line voltage directly. Type AB lamps support either method when installed according to the manufacturer's instructions.

Do high wattage LED bulbs require ballast bypass?

It depends on the model. Some lamps require ballast bypass, while others operate on a compatible existing ballast or support both installation methods. Follow the installation requirements listed on the individual product page.

What is the difference between E39 and EX39 bases?

E39 is a standard mogul screw base. EX39 is an exclusionary mogul base intended for compatible exclusionary sockets. Some EX39 lamps may also fit standard E39 sockets, but compatibility must be confirmed for the individual lamp and socket.

Can high wattage LED bulbs be used in enclosed fixtures?

Only when the individual lamp is specifically rated for enclosed-fixture use. Enclosed fixtures retain heat, and using an unrated lamp may reduce performance or shorten its operating life.

How do I know whether the bulb will fit?

Compare the lamp's maximum overall length, diameter, shape and base with the available space inside the fixture. Allow sufficient clearance for the lens, reflector and any airflow requirements listed by the manufacturer.

Are these bulbs sold individually or by the case?

Package quantities vary by product and manufacturer. Review the product page to confirm whether the displayed price applies to one bulb, a multipack or a required case quantity.

What information is needed to identify the correct replacement bulb?

Provide the model number printed on the existing bulb, the original wattage and lamp type, the base, fixture voltage, ballast model when applicable, fixture dimensions and photos of the bulb, socket and fixture.

Are these bulbs intended for household lamps?

Most products in this category are intended for commercial, industrial or outdoor fixtures rather than ordinary household table lamps. Review the specifications and application requirements before ordering.

Compare
Show 12 24 36 48 96